Introduction
Open humerus fractures resulting from gunshot wounds or blast injuries are very common. It is highly likely that every orthopaedic surgeon deployed to a combat support hospital will use an external fixator for this injury. It is also probable that every general surgeon deployed to a combat support hospital will encounter a vascular injury to the brachial artery associated with a humerus fracture. A thorough understanding of these injuries and the range of options to treat them is important.
Presentation
A blast injury from an improvised explosive device (IED) resulted in a large, lateral arm wound (Figures 1-2) and an open humerus fracture. The patient did not lose consciousness, and no other injuries were noted.
Physical examination revealed a normal vascular examination of the upper extremity. Sensory and motor functions of the median and anterior interosseous nerves were preserved. The radial, posterior interosseous, and ulnar nerves were nonfunctional, with no evident light-touch sensation or motor function in their distribution. A large metallic fragment was palpable in the axilla. Plain radiographs revealed a severely comminuted humerus fracture (Figure 3).
Management
In the operating room, the wound was
irrigated and debrided. All necrotic tissue and loose bone were removed. The palpable fragment was excised through an incision in the axilla.
Intraoperatively, the brachial plexus and brachial artery were palpable through the lateral arm wound. An external fixator was placed spanning the severely comminuted humerus fracture (Figure 4). The wounds were packed with wet-to-dry dressings soaked with Dakin’s solution. Intravenous antibiotics were administered. The patient was evacuated to a level IV medical treatment facility on postoperative day 1.
Figures
Discussion
References
Attachments:
Humerus_Fig 1.jpg (image/jpeg)
Humerus_Fig 2.jpg (image/jpeg)
Humerus_Fig 3.jpg (image/jpeg)
humerus_Fig 4.jpg (image/jpeg)