A 55-year-old patient underwent a total hip arthroplasty with a diaphyseal-locking, fully porous-coated cementless femoral prosthesis 8 years ago. Radiographs reveal a distally fixed stem with distal spot welds and proximal bone loss. The femoral head is located concentrically with the acetabulum. What is the most likely etiology of the bone loss?
1. Bone hypertrophy
2. Stress shielding
3. Osteoporosis
4. Osteolysis
5. Osteonecrosis
Figures
Answer (click for answer)
Preferred Response: (2)
Discussion: We should all associate large (>13mm), diaphyseal-filling/locking, fully porous-coated stems with stress shielding of the proximal femur. The question also mentions evidence of distal fixation (spot welds) and proximal bone loss—hallmarks of femoral stress shielding. No mention is made of radiographic bony hypertrophy, cysts or poly wear which might imply osteolysis. The key words are in the stem pointing to stress shielding. Dynamic remodeling of bone in response to changes in applied stress (Wolf’s Law) is responsible for the net loss of proximal femoral bone stock under these conditions.
Reference: Callaghan et al. (eds.) OKU: Hip and Knee Reconstruction. AAOS (1995), pp.127-138.