Year |
2001 |
|---|---|
|
Question Number |
34 |
|
Category |
Select |
Question
The number of polymer chain cross-links may be increased in ultra-high molecular weight polyethylene bearing surfaces by
1 – annealing.
2 – remelting.
3 – high-pressure molding.
4 – gamma irradiation.
5 – ethylene oxide.
Figures
Answer (click for answer)
ANSWER: 4
DISCUSSION: Gamma irradiation is a form of sterilization of prosthetic components. Bacteria are killed by the radiation. The gamma rays cause oxidation of various molecules. In the polyethylene multimer, gamma rays cause breakage of the chain via oxidation. The broken ends then spontaneously re-bond with other polyethylene chains to form additional cross-links (correct answer 4). If done in the presence of an inert gas, this process may produce a highly cross-linked plastic that may have improved resistance to wear. In the presence of oxygen, however, oxygen radicals are also formed by the irradiation. These radicals can be long-lived and cause breakdown of the polyethylene after implantation.
Reference: Beaty JH (ed): Orthopaedic Knowledge Update 6. Rosemont, IL, American Academy of Orthopaedic Surgeons, 1999, pp 47-53.