Year |
2003 |
|---|---|
|
Question Number |
44. |
|
Category |
Hip and Knee Reconstruction |
Question
Figure 9 shows the radiograph of a patient who has anterior knee pain and range of motion from 0 to 60 degrees after total knee arthroplasty. The implants are well fixed. A CT scan of femoral component shows 7 degrees of internal rotation, and the tibial components rotation is centered over the medial third of the tibial tubercle. Treatment should consist of
1- Lateral retinacular release.
2- Tibial tubercle transfer.
3- Revision of the femoral component.
4- Revision of the tibial component.
5- Proximal quadriceps realignment
Figures
Answer (click for answer)
Answer: 3
Study: CT evaluation of Miller Galante I knee system looking at rotational alignment of the femoral and tibial components and its effect on patellofemoral complications. 54 knees studies. Follow up 10 yrs. On CT the rotational position of the femoral component relative to the epicondylar axis and the position of the tibial component relative to the tibial tubercle were evaluated.
Radiographic exam ( Knee flexed at 30 degrees) examined:
1. Patellar displacement ( mean 2.7 mm )
2. patellar tilt angle ( mean 2.9 degrees)
Results:
1. Femoral and Tibial component IR was directly related to patellar maltracking. Mean Femoral internal rotation of 6 degrees. Mean rotation of tibial component 16 degrees.
2. The femoral component position had a stronger effect on patellar tracking than the tibial component
3. No radiolucency lines were detected on either components
Discussion: Proper rotational alignment is one of the most important factors in TKA. The center of the tibial component was located medially from the center of the tibial tubercle within 34% of the width of the tibial tubercle, which is the recommended alignment of many surgeons. The article also suggests that the femoral component should be inserted parallel to the epicondylar axis because slight external rotation of the femoral component relative to the posterior condylar axis is reported to provide better patellar tracking with less than 6 degrees of internal rotation seen by CT exam
Reference: Kelly, et al; Patellofemoral complications following total knee arthroplasty. Instr Course Lect 2001; 50; 403-407
Matsuda et al; Effect of femoral and tibial component position on patellar tracking following total knee arthroplasty: a 10 year follow up of miller galante I knees. Am J knee surg 2001; 14, 152-156