• O1 Network
    • Articles
    • For Residents
    • For Medical Students
    • PORT Notes
    • MSK Medicine
    • Tumor Library
    • Cases
    • Talks
    • Images
    • Viewpoints
    • Question Bank
    • Devices
    • Residency
    • Fellowships
    • Associations
    • Companies
ORTHOPAEDICSONE ARTICLES
OrthopaedicsOne Articles
  • Articles
    • Specialty
      • Arthroscopy
      • Foot and Ankle
      • Hand and Wrist
      • Hip and Knee
      • Infection
      • Joint Reconstruction
      • Musculoskeletal Medicine
      • Pediatrics
      • Shoulder and Elbow
      • Spine
      • Sports Medicine
      • Trauma
      • Tumor
    • Regional
      • Anatomy
      • Basic Science
      • Classifications
      • Diagnostic Tests
      • Evidence-Based Orthopaedics
      • Operative Techniques
      • Pain Management
      • Physical Examination
      • Pharmacology
      • Radiology
      • Rehabilitation
      • Rheumatology
      • Surgical Approaches
    • Professional
      • Bioethics
      • Economics and Health Policy
      • Epidemiology and Biostatistics
      • History of Orthopaedics
      • Informatics
      • Medicolegal
      • Mobile and Wireless
      • Practice Management
  • Reviews
    • For Residents
    • For Medical Students
  • eBooks
    • PORT Notes
    • MSK Medicine
    • Tumor Library
  • Community
    • Cases
    • Talks
    • Images
    • Viewpoints
    • Question Bank
    • Devices
  • Pages
    • Residency
    • Fellowships
    • Associations
    • Companies
  • About O1
    • Overview
    • FAQs
    • Managing Editors
    • Editorial Board
    • Content Partners
    • Participating Groups
    • Advisory Board
    • Sponsoring Organizations
    • Contact Us
  • Click to open the search input field Click to open the search input field Search
  • Menu Menu

THA fixation

1. High-Yield Overview & Design Objectives

  • Fundamental Biomechanical Objective: The primary biomechanical goal of total hip arthroplasty (THA) fixation is establishing immediate, rigid primary mechanical stability that maintains interfacial micromotion strictly below 40 to 50 μm. Interfacial micromotion exceeding 150 μm induces high shear strain that drives mesenchymal stem cell differentiation into fibroblasts, creating an unmineralized synovial-like fibrous pseudocapsule that leads to early aseptic loosening. Micromotion below 40 μm enables secondary biological osseointegration across uncemented porous lattices or stable micromechanical intertrabecular interlock within polymethylmethacrylate (PMMA) bone cement.
  • Anatomic Kinematic Replication: Precise prosthetic reconstruction requires anatomical restoration of the patient’s native center of rotation (COR), horizontal and vertical femoral offset, and leg length. In accordance with Pauwels biomechanical principles, restoring the abductor moment arm minimizes resultant hip joint reaction forces (JRF), prevents soft-tissue laxity, prevents bony and prosthetic impingement, and preserves abductor muscle efficiency throughout dynamic arcs of motion.
  • Fixation Modalities & Load Transfer Paradigms: Arthroplasty fixation encompasses three distinct biomechanical paradigms: (1) Uncemented biological press-fit fixation relying on interference fit, friction coefficient, and porous surfaces (sintered beads, fiber mesh, plasma spray, 3D-printed trabecular titanium, porous tantalum, and osteoconductive hydroxyapatite); (2) Cemented fixation utilizing PMMA as an engineered viscoelastic grout distributing compressive loads (taper-slip polished double-taper vs. composite beam matte collared stems); and (3) Hybrid constructs pairing an uncemented porous acetabular cup with a cemented polished femoral stem, combining biological socket longevity with fracture-resistant femoral load distribution.
  • Articular Constraint & Stability Spectrum: Bearing constraint exists along a continuous spectrum ranging from unconstrained neutral liners, elevated/lip-augmented liners, lateralized/offset liners, and face-changing liners to dual-mobility articulations (bearing-within-a-bearing) and mechanically locked constrained acetabular liners. Escalating constraint provides increasing intrinsic stability at the expense of higher interface shear stress transfer to the cup-bone boundary.
  • Contemporary Tribological & Materials Innovations: Critical advances include the transition from conventional gamma-irradiated UHMWPE to highly cross-linked polyethylene (HXLPE) and antioxidant (vitamin E)-stabilized polymers, low-wear ceramic-on-polyethylene (CoP) and ceramic-on-ceramic (CoC) bearing couples, 3D-printed biomimetic trabecular metal lattices matching cancellous bone modulus (2.5 to 3.5 GPa), and taper trunnion geometry optimization to mitigate mechanically assisted crevice corrosion (MACC) and trunnionosis.

2. Anatomic & Kinematic Rationale

Successful total hip reconstruction depends on the exact anatomical restoration of hip biomechanics, re-establishing physiologic load transfer, balancing the abductor envelope, and accommodating dynamic spinopelvic motion.

Hip Center of Rotation & Pauwels Biomechanics

The native hip center of rotation (COR) is located approximately 4 to 5 mm lateral to Kohler’s line (the ilioischial line) and 1 to 2 mm superior to the teardrop. In single-leg stance, the hip acts as a first-class lever pivoting about this center of rotation. In Pauwels classic static biomechanical model, the body weight force (W, representing approximately 5/6 of body weight) acts along lever arm B from the midline center of gravity to the COR. This gravitational moment is counterbalanced by abductor muscle force (Ab) acting along moment arm A from the lateral tip of the greater trochanter to the COR:

W × B = Ab × A

The resultant Joint Reaction Force (JRF) experienced across the articular surface equals the vector sum of body weight and abductor muscle tension (JRF ≈ W + Ab), typically reaching 2.5 to 3.0 times body weight during normal walking and exceeding 5.0 to 6.0 times body weight during stair climbing or stumbling. Superior and lateral displacement of the COR—frequently occurring when a reamer migrates into deficient superior bone stock—shortens the abductor moment arm (A) and lengthens the body weight lever arm (B). To maintain pelvic equilibrium, the abductor musculature must generate up to 30% to 50% greater contractile tension. This dramatic escalation in required abductor force increases the resultant JRF, precipitating muscular fatigue, chronic abductor strain, Trendelenburg lurch, and excessive shear stress at the implant-bone fixation interface. Medialization and anatomical lowering of the prosthetic COR to the teardrop optimizes the abductor mechanical advantage, diminishes resultant JRF, and minimizes interface shear stresses.

Femoral Offset Restoration & Abductor Envelope

Horizontal femoral offset represents the perpendicular distance from the center of the femoral head to the central longitudinal axis of the femoral diaphysis. Anatomical restoration of femoral offset restores resting abductor myofiber length and tension in accordance with Starling’s length-tension relationship, optimizing abductor contraction kinetics. Restoring offset also restores the lateral soft-tissue tension envelope, preventing bony impingement between the greater trochanter and the iliac wing during hip abduction and maximizing the impingement-free arc of motion.

  • Inadequate Femoral Offset: Under-restoration of offset shortens the abductor moment arm, induces abductor muscle laxity, produces an abductor lurch (Trendelenburg gait), increases resultant joint reaction forces, and allows premature prosthetic neck-on-cup or bony trochanteric impingement, predisposing to hip subluxation or dislocation.
  • Excessive Femoral Offset: Excessive lateralization of the femoral shaft increases the bending moment across the femoral stem neck-shaft junction, amplifying tensile strains on the lateral femoral cortex and elevating interface shear stresses. Clinically, over-lateralization can cause recalcitrant greater trochanteric pain syndrome, bursitis, and symptomatic iliotibial band friction.

The Lewinnek Safe Zone & The Modern Spinopelvic Paradigm

Historically, target acetabular component orientation was guided by Lewinnek’s defined “safe zone”: 40° ± 10° of radiographic inclination (abduction) and 15° ± 10° of radiographic anteversion. However, contemporary large-cohort registry and clinical retrieval analyses demonstrate that over 50% to 60% of all dislocating total hips have acetabular components positioned strictly within the classic Lewinnek safe zone. This clinical reality has driven the adoption of dynamic spinopelvic biomechanics.

The pelvis functions as an intercalated kinetic vertebra connecting the lumbar spine to the lower extremities. In an individual with normal spinopelvic mobility, transitioning from standing to a relaxed seated position is accompanied by lumbar lordosis flattening, posterior sacral rotation (sacral slope decreases), and posterior pelvic tilt (pelvic tilt increases by 15° to 25°). Biomechanically, each 1° of posterior pelvic tilt dynamically increases functional acetabular cup anteversion by approximately 0.7° to 0.8° and increases functional inclination by 0.5°. This physiological backward tilting opens the anterior acetabular socket, accommodating the flexed femur and preventing anterior femoral neck-on-cup rim impingement during seated activities.

Pathological spinopelvic stiffness alters this protective kinematic response:

  • Stiff Flatback Spine (e.g., Multi-Level Lumbar Fusion / Degenerative Spondylosis): When seated, the pelvis remains fixed and cannot tilt posteriorly. The acetabular cup remains in functional retroversion. Upon 90° of hip flexion and internal rotation, the femoral neck collides prematurely with the anterior cup rim, levering the femoral head posteriorly out of the socket.
  • Stiff Lordotic Spine: The pelvis remains fixed in anterior tilt upon standing, trapping the acetabular cup in functional retroversion. Extension and external rotation drive posterior neck-on-cup impingement, levering the femoral head anteriorly out of the socket.

Combined Anteversion Rationale

To eliminate prosthetic-on-prosthetic and bone-on-bone impingement across all functional planes, cup anteversion and femoral stem anteversion must be balanced as an interrelated unit. The classic Ranawat combined anteversion guideline dictates that the sum of operative cup anteversion and femoral stem anteversion should equal 37° ± 5° in males and 42° ± 5° in females. Widmer mathematical modeling established that optimized combined anteversion satisfies:

Combined Anteversion = Cup Anteversion + (0.7 × Stem Anteversion) ≈ 37.3°

Adhering to combined anteversion targets provides a wide, symmetrical arc of motion (≥130° of total range of motion), preventing anterior impingement in extension and external rotation, and preventing posterior impingement in deep flexion and internal rotation.

3. Materials Science & Bearing Tribology

The long-term survivorship of total hip arthroplasty is fundamentally governed by materials engineering, interface tribology, wear particle generation, and the periprosthetic host biological response.

Polymer Engineering: Conventional UHMWPE vs. HXLPE vs. Vitamin E Stabilization

Ultra-high-molecular-weight polyethylene (UHMWPE) consists of unbranched chains of polymerized ethylene with molecular weights ranging from 2 to 6 million g/mol. Historically, conventional UHMWPE was sterilized using gamma irradiation (25 to 40 kGy) in an air or oxygen-rich environment. This process generated free alkyl radicals that reacted with trapped atmospheric oxygen, triggering progressive in vivo cascade oxidation, chain scission, polymer embrittlement, and catastrophic delamination wear. Volumetric wear rates of conventional UHMWPE averaged 100 to 200 mm³/year (linear wear 0.1 to 0.25 mm/year), shedding trillions of submicron particles and driving macrophage-mediated periprosthetic osteolysis.

Highly cross-linked polyethylene (HXLPE) was engineered to overcome abrasive and adhesive wear. By subjecting the polymer to high-dose gamma or electron-beam irradiation (50 to 100 kGy), hydrogen atoms are cleaved from the polyethylene chains, creating carbon free radicals that recombine to form strong, covalent carbon-carbon cross-links between adjacent chains. This cross-linked network dramatically improves resistance to multidirectional shear strain and abrasive wear. However, irradiation leaves residual free radicals that require thermal processing:

  • Remelted HXLPE: Heated above the crystalline melting transition temperature (>135°C to 140°C). Heating allows complete recombination of residual free radicals, fully eliminating oxidative potential. However, remelting disrupts crystalline lamellae, decreasing overall crystallinity by 10% to 15%. This reduces ultimate tensile strength, yield strength, and fatigue resistance, increasing vulnerability to rim cracking in thin liners or constrained constructs.
  • Annealed HXLPE: Heated below the melting transition temperature (~110°C to 125°C). Annealing preserves native polymer crystallinity, tensile toughness, and fatigue crack resistance. However, it leaves persistent free alkyl and allyl radicals that remain susceptible to slow, progressive lipid- and oxygen-mediated oxidation in vivo.
  • Vitamin E (Alpha-Tocopherol) Stabilized HXLPE: Blending or diffusing alpha-tocopherol (0.1% to 0.3% w/w) into HXLPE provides a hydrophobic antioxidant that donates phenolic hydrogen atoms to neutralize free radicals. This eliminates the necessity for thermal remelting, thereby maintaining high polymer crystallinity, superior yield strength, and exceptional fatigue crack resistance while reducing in vivo volumetric wear rates to <5 to 15 mm³/year (linear penetration <0.02 mm/year).

Metallic Alloys, Advanced Ceramics & Bearing Couples

Modern hip arthroplasty relies on engineered metallic alloys and high-purity ceramic matrices:

  • Titanium Alloy (Ti-6Al-4V): Exhibits an elastic modulus of approximately 110 GPa (closer to cortical bone at 10 to 18 GPa than other metals), high biocompatibility, and superior bone ongrowth/ingrowth characteristics. However, Ti-6Al-4V possesses low shear resistance and notch sensitivity, making it unsuitable for direct articular bearing surfaces and vulnerable to fretting wear at modular tapers.
  • Cobalt-Chromium-Molybdenum (CoCrMo): Features an elastic modulus of 210 to 240 GPa, extreme surface hardness, and low surface roughness (Ra <0.02 μm). It is the standard metallic bearing material but is susceptible to mechanically assisted crevice corrosion and systemic release of cobalt and chromium ions.
  • Alumina Matrix Composite Ceramic (BIOLOX delta): Fourth-generation ceramic composed of 75% alumina (Al2O3), 24% zirconia (ZrO2), and 1% chromium oxide and strontium oxide. BIOLOX delta exploits phase-transformation toughening: under localized crack stress, metastable tetragonal zirconia particles transform into monoclinic crystals, expanding by 3% to 5% in volume. This volumetric expansion generates compressive hoop stresses that clamp the advancing crack tip shut, raising fracture toughness to K1c ≈ 6.5 MPa·m^1/2 and reducing catastrophic ceramic head fracture to <0.001%.

Tribological wear rates differ markedly across bearing couples:

  • Metal-on-HXLPE (MoP): Volumetric wear rates range from 10 to 25 mm³/year, well below the historical osteolysis threshold of 40 to 80 mm³/year.
  • Ceramic-on-HXLPE (CoP): Volumetric wear rates range from 5 to 15 mm³/year. Ceramic heads offer high wettability, fluid-film lubrication, and scratch resistance against third-body wear particles.
  • Ceramic-on-Ceramic (CoC): Volumetric wear rates are exceptionally low at 0.1 to 1.0 mm³/year due to fluid-film hydrodynamic lubrication. However, CoC bearings are susceptible to stripe wear during edge loading, component chipping during malseated liner insertion, and audible squeaking (incidence 0.5% to 3%).

Submicron Particulate Osteolysis & The Macrophage Cascade

Aseptic loosening is primarily driven by biological reaction to submicron wear particles (0.1 to 1.0 μm in size). Macroparticles (>10 μm) are surrounded by foreign-body giant cells without sustained osteoclastogenesis, whereas nanoparticles (<0.05 μm) enter lymphatic channels. When resident macrophages phagocytose submicron particles, toll-like receptors (TLR-4) and the intracellular NLRP3 inflammasome activate, triggering the release of pro-inflammatory cytokines: Tumor Necrosis Factor-alpha (TNF-α), Interleukin-1 beta (IL-1β), Interleukin-6 (IL-6), and Prostaglandin E2 (PGE2).

These cytokines act on surrounding osteoblasts, bone marrow stromal cells, and T-lymphocytes to upregulate Receptor Activator of Nuclear Factor-kappa B Ligand (RANKL) and downregulate osteoprotegerin (OPG), an endogenous decoy receptor. RANKL binds to the RANK receptor on CD14+ monocyte/macrophage-lineage osteoclast precursors, driving osteoclast differentiation, maturation, and bone-resorbing activity. The resulting imbalance between osteoclastogenesis and osteoblast inhibition causes progressive lacunar osteolysis, endosteal scalloping, loss of mechanical implant support, and eventual aseptic loosening.

Modular Taper Tribocorrosion & Trunnionosis (MACC)

Modular taper junctions (typically 12/14 or 11/13 male trunnions mating with female head bores) allow independent adjustment of head diameter, offset, and leg length. However, cyclic cantilever bending moments during dynamic gait generate micro-motion (fretting) between the trunnion and the head bore. This process, termed Mechanically Assisted Crevice Corrosion (MACC), initiates when fretting disrupts the passive titanium oxide or chromium oxide passivating layer.

Within the confined micro-crevice (gaps of 5 to 50 μm), fluid becomes deoxygenated, preventing re-passivation. Dissolved metallic ions hydrolyze, accumulating chloride ions and driving local crevice pH down to 1.0 to 2.0. This intense acidic environment accelerates galvanic and crevice corrosion, especially in mixed-metal couples (e.g., CoCrMo head on Ti-6Al-4V trunnion). Trunnionosis produces toxic Co2+ and Cr3+ ions, organometallic complexes, and black chromium orthophosphate corrosion debris. This debris induces Adverse Local Tissue Reactions (ALTR), cystic pseudotumor formation, abductor muscle necrosis, and severe pain. Mitigation strategies include utilizing ceramic heads (which are electrically inert and eliminate the galvanic couple), titanium intermediate adapter sleeves, larger taper contact areas, and meticulous intraoperative drying and axial impaction of tapers.

4. Constraint Spectrum & Articular Classification

Prosthetic stability exists along a continuous constraint spectrum. Increasing mechanical constraint elevates intrinsic dislocation resistance but transfers higher shear and torsional stresses directly to the cup-bone fixation interface.

Constraint Tier / Design CategoryDefining Mechanical FeaturesSoft-Tissue / Abductor RequirementsPrimary Clinical IndicationsMechanical Stress Transfer to Bone Interface
Standard Neutral LinerHemispherical 180° profile; flush flat face; maximal range of motion (ROM 130° to 140°) before neck-on-cup impingement; jump distance equals head radius (JD = r).Fully intact abductor complex; balanced soft-tissue envelope; precise anatomical component orientation.Primary total hip arthroplasty with intact anatomy, robust soft tissues, and normal neuromuscular control.Lowest shear stress transfer to cup-bone interface; physiological load distribution.
Elevated / Lip-Augmented Liner10° to 20° elevated posterior or posterosuperior rim; increases jump distance by 2 to 4 mm in the augmented arc; reduces ROM in the direction of the lip by 10° to 15°.Intact or minimally compromised abductor mechanism; mild capsular laxity.Mild posterior hip instability, focal capsular deficiency, or slight component version imperfection.Low-to-moderate shear stress; elevated rim acts as a lever arm if repetitive impingement occurs.
Lateralized / Offset LinerMedial bearing surface shifted laterally by 4 mm relative to outer cup shell; lateralizes center of rotation; increases abductor moment arm and restores abductor tension without lengthening the limb.Mild-to-moderate abductor laxity or trochanteric nonunion where limb lengthening is contraindicated.Soft-tissue laxity, high-riding greater trochanter, or revision cases with medialized acetabular cups.Moderate interface stress; increased bending moment on the acetabular shell due to lateralized COR.
Face-Changing LinerInternal articular axis tilted 10° to 20° relative to the outer shell trajectory; allows correction of effective cup inclination or anteversion without extracting a well-fixed shell.Functional abductors; instability driven primarily by component malposition.Revision THA for cup malorientation (e.g., steep inclination or retroversion) where the shell is solidly osseointegrated.Moderate-to-high localized stress concentrations; asymmetrical rim loading.
Dual-Mobility ArticulationBearing-within-a-bearing concept; large unconstrained mobile polyethylene bearing articulates with highly polished metal shell, capturing a 28 mm inner head via snap-fit ring; effective jump distance equals outer head radius (JD = Router).Tolerates severe abductor deficiency, soft-tissue laxity, or neurological impairment (Parkinson’s, dementia, stroke, spasticity).High-risk primary THA (lumbar fusion, spinopelvic stiffness, neuromuscular disorders, femoral neck fractures) and revision THA.Moderate shear stress transfer; higher volumetric wear potential due to dual articulating surfaces, mitigated by modern HXLPE; risk of intra-prosthetic dislocation (IPD).
Constrained Acetabular LinerMechanical locking ring (titanium or CoCr c-ring/clamp) capturing the femoral head beyond its 180° equator; rigidly prevents femoral head egress; restricted ROM (90° to 105°) with early neck-on-ring impingement.Zero functional abductor mechanism; complete abductor destruction or global neuromuscular instability.Recurrent catastrophic dislocation with absent abductor mechanism where dual-mobility has failed or cannot be stabilized.Maximum interfacial shear and torsional stress transfer; converts dislocation forces directly into destructive torque at the cup-bone interface, causing high rates of late cup loosening or ring breakage.

The biomechanical stability of an articulation is governed by jump distance—the vertical distance the femoral head center must translate laterally before escaping the acetabular constraint:

Jump Distance = r × (1 − cos θ)

Where r is head radius and θ is the cup opening angle. In standard hemispherical neutral cups (θ = 90°), jump distance equals the radius of the femoral head (e.g., 14 mm for a 28 mm head; 18 mm for a 36 mm head). Elevating the rim or escalating to a dual-mobility construct increases effective jump distance to that of the large outer polyethylene bearing (typically 21 to 27 mm). However, when mechanical constraint is increased via a constrained liner, subluxation forces cannot dissipate through soft-tissue displacement; instead, kinetic energy translates directly into cyclic interface shear stresses, driving accelerated aseptic loosening of the acetabular shell.

5. Component Geometry, Sizing & Modularity

Component architecture dictates primary initial mechanical stability, load transmission across host bone, and resistance to interfacial micromotion.

Acetabular Shell Geometry & Wasielewski Quadrants

Acetabular shells are designed to achieve immediate rigid scratch-fit fixation within reamed host bone:

  • Hemispherical vs. Dual-Radius Geometry: Pure hemispherical cups maintain a constant radius of curvature across their profile, providing line-to-line contact with the reamed cavity. Dual-radius (elliptical or flattened-pole) cups feature an over-dimensioned equatorial diameter (1 to 2 mm larger than the polar dimension) with a flattened apex. This geometry creates selective peripheral rim interference, generating hoop stresses that wedge the cup firmly against dense peripheral subchondral bone while preventing premature apical bottoming out, ensuring intimate peripheral bone-implant contact.
  • Porous Surface Architecture: Surface coatings provide high frictional coefficients (μ = 0.88 to 1.10) to eliminate initial micromotion. Technologies range from traditional sintered beads and fiber mesh to 3D-printed trabecular titanium and porous tantalum open-cell foams with 60% to 80% porosity and interconnecting pore sizes of 300 to 500 μm.

Transacetabular dome screw placement must strictly adhere to Wasielewski’s four-quadrant system, established by drawing a line from the anterior superior iliac spine (ASIS) through the acetabular center to the fovea, crossed perpendicularly by a second line at the acetabular center:

  • Posterosuperior Quadrant (Primary Safe Zone): Contains the thickest bone stock within the posterior column and sciatic buttress. Dome screws measuring 25 to 35 mm can be safely inserted without neurovascular jeopardy.
  • Posteroinferior Quadrant (Secondary Safe Zone / Conditional): Contains bone overlying the ischium. Screws <20 to 25 mm are safe; screws >25 mm risk penetrating into the greater or lesser sciatic notch, threatening the inferior gluteal neurovascular bundle, internal pudendal vessels, and the sciatic nerve.
  • Anterosuperior Quadrant (The “Death Quadrant”): Directly abuts the external iliac artery and vein. Screw penetration through the inner pelvic cortex risks fatal vascular laceration or pseudoaneurysm. Screws are strictly contraindicated.
  • Anteroinferior Quadrant (Danger Zone): Directly overlies the obturator canal transmitting the obturator nerve, artery, and vein. Transcortical screw placement carries high risk of neurovascular injury and must be avoided.

Femoral Stem Geometry Classifications (Khanuja System)

Modern uncemented femoral stems are categorized according to the Khanuja morphological classification based on their cross-sectional geometry, plane of taper, and primary site of load transmission:

  • Type 1: Single-Wedge (Tapered Wedge): Flat mediolateral profile with a rectangular or trapezoidal cross-section, tapered primarily in the coronal plane with proximal porous coating. Achieves primary axial and torsional stability by engaging the medial and lateral metaphyseal cortices. Highly forgiving in Dorr Type A and B canals (e.g., Taperloc, Accolade).
  • Type 2: Double-Wedge (Metaphyseal Fit-and-Fill): Tapered in both anteroposterior and mediolateral planes. Fills the proximal metaphyseal envelope with circumferential proximal porous coating, achieving excellent rotational resistance in Dorr Type B bone (e.g., Corail, Anthology).
  • Type 3: Tapered Rectangular (Wagner Type / SL-Plus): Straight stem with a rectangular cross-section featuring four sharp longitudinal corners. The sharp corners cut into endosteal bone, providing exceptional rotational stability. Highly versatile in Dorr Type A, B, and dysplastic femurs.
  • Type 4: Cylindrical Fully Porous Coated: Extensively porous-coated cobalt-chromium or titanium stems designed for diaphyseal scratch-fit over 4 to 6 cm of cylindrical diaphysis. Provides rigid primary stability in metaphyses with severe bone deficiency, but structural stiffness induces profound proximal stress shielding (Gruen zones 1 and 7) and mid-thigh pain (e.g., AML, Solution).
  • Type 5: Modular Fluted Tapered: Conical stem geometry with longitudinal splines/flutes and a 2° to 3.5° taper angle. Longitudinal splines engage diaphyseal cortices to provide rotational stability, while the taper converts axial loads into radial hoop compression. Modular proximal bodies permit independent adjustment of version, height, and offset. The gold standard for Paprosky Type II/III revision bone loss and periprosthetic fractures.
  • Type 6: Anatomical Stems: Feature an anteverted proximal neck and a sigmoid sagittal bow mimicking native anterior femoral curvature. Requires side-specific left and right implants to match the metaphyseal-diaphyseal flare (e.g., Lubinus, SPS).

Cemented Stem Mechanical Philosophies: Taper-Slip vs. Composite Beam

Cemented femoral stem designs adhere to two contrasting biomechanical philosophies:

  • Taper-Slip Philosophy (Force-Closed / Polished Double-Taper): Exemplified by the Exeter stem. Features a collarless, highly polished surface (Ra <0.05 μm) with a double or triple taper. The stem is engineered to debond at the stem-cement interface. Under cyclic physiological loading, the polished stem undergoes controlled microscopic subsidence (0.5 to 1.5 mm over several years) within the cement mantle. This controlled taper-slip converts vertical shear stresses into radial hoop compressive stresses, exploiting PMMA’s high compressive strength (80 to 100 MPa) and continuous viscoelastic creep, maintaining the construct in a self-tightening, prestressed configuration.
  • Composite Beam Philosophy (Shape-Closed / Matte Collared): Exemplified by the original Charnley and contemporary matte stems. Features a matte or satin finish (Ra 0.5 to 1.0 μm), rectangular cross-section, and a broad medial calcar collar. The design demands an unbroken, permanent mechanical bond between the stem, cement, and bone, acting structurally as a single unified beam. If interface debonding occurs, the rough matte surface generates abrasive cement fretting wear debris, precipitating rapid cement mantle fragmentation and early aseptic loosening.

6. Fixation Mechanics & Bone Interface

Fixation durability depends on establishing an intimate mechanical interlock that limits interfacial micromotion, followed by biological bone ingrowth or stable cement mantle viscoelastic load transmission.

Cementless Biological Fixation & Osseointegration Thresholds

Biological fixation progresses through two distinct phases: primary mechanical stability followed by secondary osseointegration. Primary stability is achieved intraoperatively through press-fit interference. On the acetabular side, under-reaming the cavity by 1 to 2 mm relative to the outer cup diameter creates peripheral rim hoop stresses that resist toggle and shear. On the femoral side, sequential compaction broaching compresses cancellous bone to create axial and torsional resistance. The critical biomechanical threshold is interfacial micromotion:

  • Micromotion <40 to 50 μm: Essential for direct osteoblastic adhesion, osteoid deposition, and primary woven bone formation, which subsequently remodels into mature load-bearing lamellar osseointegration.
  • Micromotion 50 to 150 μm: Results in mixed bone ingrowth and fibrous tissue encapsulation; unstable under high peak physiological loading.
  • Micromotion >150 μm: Prevents vascular invasion and osteogenesis. Mesenchymal stem cells differentiate into fibroblasts, creating an intervening synovial-like fibrous pseudocapsule that manifests clinically as implant loosening.

Advanced porous biomaterials optimize biological ingrowth:

  • Pore Architecture: Interconnected pore diameters of 100 to 400 μm are biologically optimal for vascularized osteon colonization. Highly porous metals (porous tantalum and 3D-printed trabecular titanium) exhibit 60% to 80% open-cell porosity and high coefficient of friction (μ = 0.88 to 1.10). Their compressive elastic modulus (2.5 to 3.5 GPa) closely matches subchondral trabecular bone (1 to 2 GPa), reducing interfacial shear stress.
  • Hydroxyapatite (HA) Coatings: Thin (50 μm), highly crystalline (>60%) plasma-sprayed ceramic layers that act as osteoconductive scaffolds. HA releases calcium and phosphate ions into the peri-implant gap, stimulating rapid bone bridging across gaps up to 1 to 2 mm and providing a biological seal against wear debris migration.

Biological fixation stability is graded radiographically using the classic Engh criteria:

  • Engh Bone Ingrowth Fixation: Endosteal “spot welds” crossing into porous surfaces; absence of radiolucent lines along porous coating; cortical thickening at transition zones; absence of a distal pedestal.
  • Engh Stable Fibrous Fixation: Parallel, non-progressive radiolucent lines (<1 mm) with a sclerotic reactive border along the porous coating; absence of progressive subsidence (<1 mm); stable distal pedestal.
  • Engh Unstable Fixation: Divergent, widening radiolucent lines (>2 mm); progressive subsidence (>2 mm); stem tilt in varus/valgus; lack of spot welds; dense reactive pedestal formation.

Cemented PMMA Microinterlock & 3rd-Generation Technique

Polymethylmethacrylate (PMMA) does not function as a biological adhesive glue; it is an engineered viscoelastic grout that transfers compressive and shear loads from a stiff metallic implant to surrounding trabeculae. Durable fixation requires achieving 2 to 4 mm of cancellous intertrabecular penetration, creating a three-dimensional composite. Cement mantles under 2 mm demonstrate increased fatigue cracking due to excessive bending strain, whereas mantles exceeding 5 mm generate excessive exothermic polymerization temperatures and increase bone thermal necrosis risk without mechanical benefit.

Modern 3rd-generation cementing technique requires strict adherence to seven sequential principles:

  • 1. Distal Intramedullary Plug: Size and deploy a dedicated polyethylene or PMMA restrictor exactly 1 to 2 cm distal to the planned stem tip to establish a rigid distal floor.
  • 2. Pulsatile Lavage: Perform high-pressure pulsatile saline lavage of the femoral canal to clear bone marrow fat, hematoma, and cellular debris from the cancellous trabeculae.
  • 3. Canal Drying & Hemostasis: Pack the canal sequentially with gauze soaked in dilute epinephrine (or hydrogen peroxide) followed by continuous suction catheter placement until the canal is completely dry. PMMA must never be injected into pooling blood.
  • 4. Vacuum Mixing: Mix high-viscosity PMMA under sub-atmospheric vacuum (<200 mbar) to evacuate air bubbles, reducing microporosity from 10% to under 2% and significantly improving fatigue life.
  • 5. Retrograde Injection: Deliver cement into the femoral canal using a long-nozzle delivery gun starting immediately above the distal plug, withdrawing the nozzle tip slowly while keeping it submerged within the rising cement column to avoid air lamination.
  • 6. Proximal Pressurization: Apply a soft rubber proximal pressurizer seal over the canal entry and deploy sustained mechanical pressurization for 1 to 2 minutes, forcing liquid cement into cancellous spaces.
  • 7. Centralized Stem Insertion: Mount the polished stem with a distal centralizer and advance it in neutral alignment down the femoral axis. Maintain sustained manual pressure without toggle or movement until exothermic polymerization completes.

Barrack Mantle Grading provides the standard radiographic quality assessment:

  • Grade A: Complete cement “whiteout” with zero radiolucency at the cement-bone interface; continuous mantle >2 mm in all Gruen zones.
  • Grade B: Slight radiolucency involving <50% of the cement-bone interface on AP and lateral projections.
  • Grade C: Radiolucency involving 50% to 99% of interface, or any mantle defect/thinning <1 mm in any zone.
  • Grade D: Complete 100% radiolucency in any projection, or direct stem-cortical contact (zero mantle) in any zone.

Radiographic Zone Localization

Interface remodeling and loosening are tracked systematically via established zone systems:

  • Acetabular DeLee and Charnley Zones: On an AP pelvis radiograph, the periprosthetic acetabulum is divided into three equal segments: Zone I (superior weight-bearing dome), Zone II (middle third adjacent to the quadrilateral plate and teardrop), and Zone III (inferior third encompassing the obturator foramen rim).
  • Femoral Gruen Zones (AP Radiograph): The femoral periprosthetic interface is divided into seven zones on the AP view: Zone 1 (greater trochanter), Zone 2 (lateral proximal metaphysis), Zone 3 (lateral mid-diaphysis), Zone 4 (distal stem tip), Zone 5 (medial mid-diaphysis), Zone 6 (medial proximal metaphysis), and Zone 7 (calcar femorale and lesser trochanter).
  • Femoral Gruen Zones (Lateral Radiograph): Divided into seven zones on the cross-table lateral view: Zone 8 (anterior proximal), Zone 9 (anterior mid), Zone 10 (anterior distal), Zone 11 (distal stem tip), Zone 12 (posterior distal), Zone 13 (posterior mid), and Zone 14 (posterior proximal).

7. Component Selection & Surgical Balancing Principles

Implant selection must be tailored to host bone quality, femoral canal morphology, spinopelvic kinematics, and patient age.

Morphological Canal Assessment: The Dorr Classification

  • Dorr Type A: Champagne-flute canal characterized by thick, dense cortices, a narrow diaphyseal canal, and a high Canal Flare Index (CFI >4.7). Accommodates metaphyseal-engaging uncemented tapered wedge stems. Technical caveat: Dense bone resists broach compaction, markedly increasing hoop-stress burst fracture risk during preparation; prophylactic calcar cerclage wiring is considered if resistance is severe.
  • Dorr Type B: Transitional morphology with moderate cortical thickness and gradual proximal-to-distal taper (CFI 3.0 to 4.7). Versatile architecture accommodating uncemented tapered wedge, fit-and-fill, or cemented stems with high predictability.
  • Dorr Type C: Stovepipe canal characterized by thin, porous cortices, wide cylindrical diaphysis, and loss of structural architecture (CFI <3.0). Strongly indicates cemented femoral stem fixation. Attempting uncemented fixation in Dorr C canals carries a high risk of axial subsidence (>5 mm), rotational instability, and early periprosthetic fracture.

Bone Quality, DEXA T-Scores & Age Stratification

Preoperative Dual-Energy X-ray Absorptiometry (DEXA) evaluation is indicated in patients over 65 years or those with risk factors for metabolic bone disease. A femoral neck T-score < -2.5 (osteoporosis) correlates with impaired biological ingrowth and a dramatic increase in intraoperative and early postoperative periprosthetic fractures when uncemented stems are used. In osteoporotic bone, cemented femoral fixation is strongly recommended to achieve immediate intertrabecular interlock and bypass dependence on host cellular osteogenesis.

Selection matrix by patient age and demand:

  • Young, Active Patients (<65 to 70 Years): Fully uncemented constructs (porous cup and tapered stem) preserve host bone stock, allow dynamic physiological remodeling, and provide lifetime osseointegration.
  • Elderly Patients (>75 to 80 Years) or Osteoporotic Bone: Cemented polished double-taper femoral stems (or hybrid THA: uncemented cup + cemented stem) eliminate the 2.5-fold higher risk of early periprosthetic fracture seen with uncemented stems while providing immediate full weight-bearing.
  • Intermediate Cohort (65 to 75 Years): Hybrid THA (uncemented porous cup + cemented polished stem) combines the superior 20-year socket survivorship of uncemented cups with the fracture-resistant, forgiving load distribution of cemented stems.

Combined Anteversion & Spinopelvic Functional Balancing

Surgical cup positioning must integrate dynamic spinopelvic classification:

  • Flexible Spine / Normal Pelvic Mobility: Standard cup inclination (40° ± 5°) and anteversion (20° ± 5°) achieving combined anteversion of 35° to 45°.
  • Stiff Spine / Fused Lumbar Kyphosis (Flatback): Pelvis fails to tilt posteriorly upon sitting. Target increased standing cup anteversion (22° to 26°) and inclination (42° to 45°) to provide sufficient anterior clearance and prevent seated posterior dislocation, or utilize a dual-mobility bearing.
  • Stiff Lordotic Spine: Pelvis remains fixed in anterior tilt upon standing. Avoid excessive cup anteversion (≤15°) to prevent anterior dislocation in standing extension.

8. Long-Term Registry Survivorship & Clinical Outcomes

National joint replacement registries and long-term randomized clinical trials provide definitive evidence regarding total hip arthroplasty fixation longevity across diverse patient populations.

  • American Joint Replacement Registry (AJRR): Tracking over 2.5 million procedures, AJRR data confirm cumulative 10-year all-cause primary THA survivorship exceeding 92% to 94%. Uncemented fixation represents >93% of primary femoral stems in North America. However, AJRR registry analyses highlight that periprosthetic fracture represents the primary indication for early revision (<90 days) in uncemented femoral stems, occurring predominantly in female patients aged >70 years with Dorr Type B and C canals.
  • National Joint Registry (NJR) for England and Wales: Tracking over 1.4 million primary procedures, NJR reports identify hybrid fixation (uncemented cup + cemented polished stem) as having the lowest cumulative revision rates at 15 to 20 years across patients aged 65 to 75 years (revision rate <4.5% at 15 years, survivorship >95.5%). In patients >75 years, cemented stems exhibit significantly superior survivorship compared to uncemented stems, which suffer from a substantially higher rate of early revision for periprosthetic fracture. Pennington et al. (BMJ 2013) health economic analysis of 44,234 NJR patients confirmed that cemented THA is the most cost-effective fixation strategy across most age strata, whereas uncemented fixation carried higher initial implant costs without clinical superiority.
  • Swedish Hip Arthroplasty Register (SHAR): Demonstrates 20- to 25-year cemented femoral stem survivorship exceeding 90% for polished double-taper designs. Callaghan et al. (JBJS Am 2000) landmark 25-year cohort confirmed 86% stem survival for aseptic loosening and 81% overall at 25-year follow-up. Modern uncemented cups paired with HXLPE liners have achieved parity with cemented sockets, establishing hybrid THA as the benchmark construct for intermediate-to-elderly European populations.
  • Australian Orthopaedic Association NJRR (AOANJRR): Confirms that uncemented femoral stems in patients ≥75 years carry a 2.5-fold higher hazard ratio for revision secondary to periprosthetic fracture within the first 12 postoperative months compared to cemented stems. Conversely, in patients <55 years, uncemented stems and cups provide superior long-term survivorship (>95% at 15 years), avoiding long-term cement mantle fatigue failure. Batailler et al. (J Arthroplasty 2020) prospective Level I randomized controlled trial at 10-year follow-up demonstrated 98.7% cemented vs. 97.4% uncemented 10-year stem survival (p=0.62), confirming equivalent durability when implants are matched to bone quality. Abdulkarim et al. (Orthop Rev 2013) meta-analysis of 9 RCTs (1,470 hips) found no difference in overall survival or Harris Hip Score between cemented and uncemented fixation, but documented a significantly elevated risk of intraoperative and early periprosthetic fracture with uncemented stems.

9. Prosthesis-Specific Complications & Failure Modes

Prosthesis failure in total hip arthroplasty results from mechanical, materials science, or biological degradation of the fixation interface or bearing couple.

Complication / Failure ModeUnderlying Biomechanical MechanismImplant Design FactorsPrevention & Management Strategy
Intraoperative Periprosthetic Burst / Hoop-Stress FractureWedge expansion of an uncemented stem exceeding cortical tensile strain capacity (hoop stress > cortical yield strength of 100 to 130 MPa) during final broaching or stem impaction.Bulky proximal geometries; aggressively tapered single or double wedges; cylindrical diaphyseal stems in narrow champagne-flute (Dorr A) canals.Ensure generous lateral trochanteric relief with box osteotome; avoid aggressive broach impaction; place prophylactic calcar cerclage wire prior to final broaching in Dorr A canals; manage with cerclage wiring or stem revision.
Bone Cement Implantation Syndrome (BCIS) Grade 1 to 3High intramedullary pressurization during PMMA insertion forces marrow fat, methylmethacrylate monomer, micro-air bubbles, and thromboplastic tissue into open femoral venous sinusoids, causing pulmonary micro-embolization, pulmonary vasoconstriction, acute right ventricular strain, and circulatory collapse.Unvented distal plugs; high-viscosity cement pressurization without vacuum mixing; lack of canal venting.Grade 1 (BP drop >20%), Grade 2 (BP drop >40% or SpO2 <88%), Grade 3 (cardiovascular collapse requiring CPR). Thorough pulsatile lavage and canal drying; vent canal; 100% FiO2 during cementing; invasive arterial line monitoring; immediate vasopressor support (epinephrine/norepinephrine).
Trunnionosis & Mechanically Assisted Crevice Corrosion (MACC)Cyclic cantilever bending moments create fretting micro-motion at the modular head-neck taper interface, breaching the passive oxide layer; stagnant crevice fluid acidifies (pH 1 to 2), driving galvanic and crevice corrosion.Large diameter femoral heads (≥36 mm) with short taper trunnions (12/14 tapers); mismatched alloys (CoCrMo head on Ti-6Al-4V neck); high-offset stem necks increasing bending moment.Clean and dry trunnion prior to impaction; axial impaction blow; use ceramic heads or titanium adapter sleeves; avoid large CoCr heads on high-offset stems; revision with modular sleeve replacement and ceramic head exchange.
Aseptic Loosening & Proximal Stress ShieldingStructural stiffness mismatch between metal prosthesis and cortical bone bypasses proximal metaphysis (Wolff’s law), causing calcar resorption; wear debris induces macrophage phagocytosis, RANKL upregulation, and periprosthetic osteolysis.High-modulus CoCrMo alloys (~210 GPa); fully porous-coated cylindrical stems; thin UHMWPE liners (<6 mm); suboptimal cement mantle (<2 mm, Barrack Grade C/D).Low-modulus titanium alloys (~110 GPa); proximally coated tapered wedge designs; highly cross-linked polyethylene (HXLPE) or ceramic bearings; 3rd-generation cementing achieving Barrack Grade A mantle; revision with porous metaphyseal sleeves/cones or fluted tapered stems.
Recurrent Dislocation & Prosthetic ImpingementComponent malorientation, spinopelvic mismatch, or inadequate abductor tension causing prosthetic or bony impingement; femoral head levers out of cup when translation exceeds jump distance.Small femoral head diameter (28 mm); shallow cup depth; non-skirted vs. skirted modular heads; lack of dual-mobility mechanics in high-risk patients.Optimize combined anteversion (35° to 45°); restore femoral offset and abductor tension; use ≥32 mm or 36 mm heads with HXLPE; dual-mobility bearings for spinopelvic stiffness; constrained liners reserved for global abductor loss.
Ceramic Liner Mismatch / Stripe Wear & SqueakingEdge loading during micro-separation or stripe wear where fluid-film lubrication is disrupted, causing high frictional torque and acoustical resonance.Steep acetabular inclination (>45°); hard-on-hard CoC articulation; ceramic liner malseating/chipping during insertion.Avoid steep cup inclination (<40° to 45°); ensure pristine seating of taper-in-cup ceramic liner without cross-threading; consider CoP (ceramic head on HXLPE) to eliminate squeaking risk entirely.

10. Evidence-Based Synthesis

Modern clinical decision-making is grounded in high-quality randomized controlled trials and prospective registry analyses, corroborated by seminal biomechanical and anatomical descriptions.

Clinical Question / InvestigationLevel of EvidencePivotal Landmark StudyStudy Design & MethodologyCohort Size / Follow-upPrimary Outcome / Effect SizeDOI
Biological fixation & osseointegration criteria in porous-coated femoral stemsLevel IVEngh CA, Bobyn JD, Glassman AH (1987)Seminal Observational Cohort Study269 hips (AML porous stem); mean 4.2 years follow-up (up to 7 years)Established classic radiographic criteria for osseointegration vs. fibrous stability; bone ingrowth confirmed in 84% with stable fixation.DOI
Long-term survivorship and failure modes of cemented femoral and acetabular fixationLevel IVCallaghan JJ, Albright JC, Goetz DD et al (2000)Long-Term Retrospective Cohort Study330 primary THAs (262 patients); minimum 25-year follow-up (mean 27 years)25-year femoral component survival of 86% for aseptic loosening and 81% overall; confirmed long-term durability of cemented femoral fixation.DOI
Comparative implant survival and functional scores of cemented vs. uncemented THA fixationLevel IAbdulkarim A, Ellanti P, Motterlini N et al (2013)Systematic Review & Meta-Analysis of RCTs9 RCTs, 1,289 patients (1,470 hips); follow-up 1 to 10 yearsNo significant difference in overall implant survival or Harris Hip Score; uncemented stems had higher intraoperative/early periprosthetic fracture risk.DOI
10-year comparative survivorship and osteolysis of cemented vs. uncemented femoral stemsLevel IBatailler C, Malemo Y, Demey G et al (2020)Prospective Randomized Controlled Trial160 patients randomized (80 cemented vs. 80 uncemented); minimum 10-year follow-up10-year stem survival for aseptic loosening: 98.7% cemented vs. 97.4% uncemented (p=0.62); equivalent clinical and radiographic longevity.DOI
Cost-effectiveness and long-term revision risk across cemented, cementless, and hybrid fixationsLevel IIPennington M, Grieve R, Sekhon JS et al (2013)National Registry Cohort & Health Economic Decision Analysis44,234 patients from National Joint Registry (NJR) for England and Wales; up to 8 years follow-upCemented THA was the most cost-effective fixation strategy across most patient age strata; uncemented fixation carried higher initial implant costs without superior survival.DOI

11. References

  • Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987. doi:10.1302/0301-620X.69B1.3818732 [Level IV: Seminal Observational Cohort Study]
  • Callaghan JJ, Albright JC, Goetz DD et al. Charnley total hip arthroplasty with cement. Minimum twenty-five-year follow-up. J Bone Joint Surg Am. 2000. doi:10.2106/00004623-200004000-00004 [Level IV: Long-Term Retrospective Cohort Study]
  • Abdulkarim A, Ellanti P, Motterlini N et al. Cemented versus uncemented fixation in total hip replacement: a systematic review and meta-analysis of randomized controlled trials. Orthop Rev (Pavia). 2013. doi:10.4081/or.2013.e8 [Level I: Systematic Review & Meta-Analysis of RCTs]
  • Batailler C, Malemo Y, Demey G et al. Cemented vs Uncemented Femoral Components: A Randomized, Controlled Trial at 10 Years Minimum Follow-Up. J Arthroplasty. 2020. doi:10.1016/j.arth.2020.03.043 [Level I: Prospective Randomized Controlled Trial]
  • Pennington M, Grieve R, Sekhon JS et al. Cemented, cementless, and hybrid prostheses for total hip replacement: cost effectiveness analysis. BMJ. 2013. doi:10.1136/bmj.f1026 [Level II: National Registry Cohort & Health Economic Decision Analysis]

12. Master Class Pro-Tip

In uncemented femoral preparation, the primary determinant of stem alignment and hoop-stress fracture risk is the lateral trochanteric envelope. Inadequate clearance of the dense posterolateral greater trochanteric overhang forces broaches into varus, risking calcar blowout and early stem toggle. Always utilize a dedicated box osteotome or lateralizing burr to remove this overhang down to the true neutral endosteal axis before introducing compaction broaches. Conversely, for cemented femoral fixation, PMMA is an engineered grout, not a biological glue; durability is completely dependent upon cancellous intertrabecular penetration. Never insert cement by hand or into a pooling hematoma. Meticulously execute third-generation technique: place a distal plug 1 to 2 cm distal to the planned stem tip, perform high-pressure pulsatile lavage, aggressively dry the canal with dilute epinephrine packing and continuous catheter suction, vacuum-mix high-viscosity PMMA to eliminate micro-voids, inject retrograde via a long nozzle, and maintain sustained proximal pressurization for 1 to 2 minutes before introducing a centralized polished stem. This ensures a flawless, bubble-free 2 to 4 mm mantle that self-tightens over decades of physiologic loading.

Master Class Surgical Pearl: Biomechanical Balancing and Fixation in THA Fixation

Last Updated on September 29, 2026

🔗 Knowledge Graph & Clinical Correlates

OrthopaedicsOne Living Semantic Network

🛠️ Operative Techniques

  • Valgus osteotomy for Perthes disease Pediatrics
  • Valgus osteotomy for development coxa vara Hip and Knee

🩺 Clinical Conditions & Indications

  • Which EMR should I choose Original Clinical Contribution: Authored for the OrthopaedicsOne General Orthopaedics Specialty Section. Preserved, digitized, and updated to modern evidence-based...

🔬 Anatomy, Pathology & Diagnostics

  • Why I Would Not Consider Navigating My THA Hip Joint & Proximal Femur
  • Why I Would Consider Navigating My THA Hip Joint & Proximal Femur
  • Why I Use Metal on Metal Hip Joint & Proximal Femur
  • Why I Use Cross-Linked Polyethylene Hip Joint & Proximal Femur

🕸️ Semantic Relations (RDF)

ABOUT

  • Overview
  • FAQs
  • Managing Editors
  • Editorial Board
  • Content Partners
  • Participating Groups
  • Advisory Board
  • Sponsoring Organizations
  • Contact Us

ARTICLES

  • Arthroscopy
  • Foot and Ankle
  • Hand and Wrist
  • Hip and Knee
  • Infection
  • Joint Reconstruction
  • Musculoskeletal Medicine
  • Pediatrics
  • Shoulder and Elbow
  • Spine
  • Sports Medicine
  • Trauma
  • Tumor

REVIEWS

  • For Residents
  • For Medical Students

EBOOKS

  • PORT Notes
  • MSK Medicine
  • Tumor Library

COMMUNITY

  • Talks
  • Images
  • Viewpoints
  • Question Bank
  • Devices

PAGES

  • Residency
  • Fellowships
  • Associations
  • Companies
Copyright © 2012-2026 OrthopaedicsOne | Privacy Policy | Dr. Christian Veillette . Powered by: OrthoNet - Empowering the Future of Orthopaedic Care
Scroll to top Scroll to top Scroll to top